Possible defects and their remedy
Defect
Control light "power net"
is not lighting
The light "burner switch"
is not lighting
The boiler cannot reach
demanded parameters
Door not sealed
Cause
There is no voltage in the main
Plug is not plugged properly
Damaged switch
Cord damaged
No need of heating
Interrupted safety
thermostat
Damaged switch
Lack of water in system
Too high pump output
Boiler output is not
dimensioned sufficiently
for the system
Bad quality of fuel
Weak chimney drought
Strong chimney drought
Defect of the burner
Damaged packing cord
19
Remedy
Check
Check
Replace
Replace
Find the cause, remove it and then reset
Replace
Re-fill
Regulate the flow and switching
Mistake in project
Use the prescribed fuel only
New chimney, remove wrong attachment
Place a cut-off slide into exhaust
pipe
See the supplement No.1, Or No.2 -
Searching defects
Replace
, set up the hinges