Starting the pellet burner

The burner starts the stand-by mode automatically by switching on the main switch of the
boiler. The burner starts the opetation by switching on the burner switch and turning the
boiler thermostat to required boiler temperature. According to need of heat the burner
ignites and burns the pellets until the boiler thermostat cuts out. As an alternative, the
burner is controlled by the temperature sensor connected to the TS1 port on the right upper
side of circuit board. Be sure that its contacts lock properly in a place.
Stopping the pellet burner
The burner is stopped by the operating thermostat cutting out, by switching off the burner
switch (the stand-by mode) or through the burn down iniciated via menu.

Emergency stop

NOTE:
In case of emergency, the burner can be stopped by switching off the main boiler switch and
disconnecting from the mains.