Voiler for combustion of wooden pellets

Advertisement

The fuel is feeded, ignitted, but the ventilator does not start:
Check
Fuse of fan motor (damaged)
Ventilator including the cable
Motor of ventilator (damaged)
The fuel is feeded, ignitted, ventilator starts, but then the feeder does not start:
Check
Photocell (dirty)
Photocell (damaged)
The appliance stopped, it does not work after restarting:
Photocell has interrupted its function by inperfect combustion.
Check
Photocell sensitivity, on P5
When the appliance does not start:
Possible operational defect caused by:
- photocell
- heating spiral
- fuses inside the service box
If the appliance does not start in despite of searching for the defects, please, call the
professional service organization.
Remedy
- replace
- test
- replace
Remedy
- clean
- replace
Remedy
Check the LD1 during operation
(LD1 should light on, when the flame
is burning in the burner).