Safety - ATTACK PELLET Series Instructions For Use Manual

Voiler for combustion of wooden pellets

Advertisement

SAFETY

The appliance can be tested or ran into operation only when it is attached to the boiler and
the thus the flue gas can be illimitably leaded away to the external space through the flue
pipe or chimney.
The chimney chaplet is to be installed to assure the constant chimney drought also in
atmospheric exposure and exclude the possibility of backfire the flue gas in the chimney.
Underpressure in the boiler fire chamber should be min. 5 - 6 Pa (0,5 - 0,6 mm of water
column).
The pellets have to be kept on the dry and well ventilated place.
The device is sized only for burning wooden pellets of diameter 6 - 10 mm.
!
NOTE: Use the mouth protection in manipulation with the pellets !
The boiler room, where the appliance is to be installed, has to fitt the local norms of fire
protection.
!
WARNING: The electrical installation can be provided by the profesional
electrician only!
It is forbidden to provide any changes or remakes on the appliance without written
agreement of the producer.
It is forbidden to install another spare parts mismatched of producer specification, that can
cause inadvisability of the burner, without written agreement of the producer.
The burner cannot be installed in the place of impending fire.
The combustible material cannot be kept near the burner.
Before the contingent welding the appliance has to be disconnected from the main and the
control pannel has to be demounted.
No openings can be opened during the operation.
3