Voiler for combustion of wooden pellets

Advertisement

Before cleaning the burner from ash it is necessary:
- To turn off the heating requirement by switching off the
burner switch. The fan stays in operation for approx. 4
minutes (burning out phase).
- To switch off the main switch on boiler control board after
the fan stops (cca 4 min.) and let the burner cool down to
avoid scorching.
- To remove the fitting screws (eventually open the door
where the burner is installed -it depends on boiler
modification) and remove the burner from the boiler.
- To remove the grate and clean it.
- Clean the burner carefully and also the boiler - if
necessary, from the soft and hard ash.
- Clean the ignition plate and its openings very carefully
from soft and hard ash.
NOTE:
Push the plane part back of the grate back under the
ingition plate as far as possible.
!
CAUTION: Use the protecting gloves and
eyeglasses during soft and hard ash removal!
Clean the photocell if necessary.
Cleaning/checking of photocell :
- remove the photocell
- clean the photocell from the soot using the wet clout
- check the location of clamping ring on the photocell
-
put the photocell in again
!
CAUTION: It is necessary to disconnect the
appliance from the main and remove the control board before eventual welding on the
appliance.
Maintenance schedule
1. 2-4 times per month (regarding pellet quality):
2. 1 time per month:
3. 1 time per month:
4. 1 time per quater:
5. 1 time per year:
remove the soft and hard ash
clean the falling shaft and tube
clean the flue channels (moving the pull-rod of turbulators) and
convective parts of the boiler
(the more frequently, the higher efficiency).
Clean the storage for pellets from saw dust
Check the burner settings with the appropriate appliances
(contact your seller or installer).
10
Ignition
Plate
grate
photocell