The settings of control electronics
Potentiometers P1- P5 are potentiometers for fine settings of burner functions.
The control panel has three light diodes (LD1,LD2,LD3).
Functions P1- P5
Pot.
Function
P- 1
Interval of feeding
P- 2
Feeding cycle
P- 3
Burning out time
P- 4
Transitional interval
(starts with 25% feeding)
P- 5
Photocell sensitivity
Reading the values on potentiometer
For reading the value set on given potentiometer firstly the green diode LD3 is blinking for
given potentiometer and follow on yellow diode LD2 blinking for the value set on this
potentiometer. This is done continuously - Pot. 1, 2, 3, 4, 5, 1, 2, .... - no matter if the burner is in
operational or stand-by mode.
For example: 3 x green blink is followed by 6 x yellow blink - it means that P-3 is set to burning
out time of 210 seconds, after the photocell has detected the flame. (see Tabel of settings).
!
CAUTION Do not change any values during the operation time - high voltage
on the control panel !
Range of settings
30 - 165 sec.
1,5 - 8,21 sec.
30 - 300 sec.
45 - 450 sec.
0 - 9
:
Description/Note
Pellets should lightly cover upper
ignition openings of the grate;
approximatelly 0,2-0,25 l.
Time of pellet feeding every 15 sec.
Fan running time, when the photocell
does not detect the flame.
Time between ignition and normal
operation.
9 = max. sensitivity on light/flame
0 = min. sensitivity on light/flame