CONNECTION TO THE ACCUMULATION TANKS ..............17 WARRANTY CONDITIONS ..........................19 TECHNICAL PARAMETERS ..........................20 DIMENSIONS OF THE BOILER ATTACK WOOD&PELLET 25 ............21 REGULATION OF THE BOILER AND THE HEATING SYSTEM ..............22 IN GENERAL ..............................22 EMERGENCY ACTIONS ..........................22 PREPARATION FOR THE OPERATION, FILLING THE INTEGRATED PELLET TANK ....
Page 4
12 TIMER SETTINGS ............................... 69 13 SOFTWARE UPDATES ............................70 14 FACTORY SETTINGS AND FILES LOADING ....................72 15 FAULTS OF THE BOILER ATTACK WOOD & PELLET ................73 16 BOILER MAINTENANCE ..........................73 17 BOILER CLEANING ............................74 18 ASSEMBLY AND DISSASSEMBLY OF THE REFRACTORY ITEMS ............75 19 TABLE OF RELATION OF THE RESISTANCE AND THE TEMPERATURE OF THE SENSOR PT 1000 .....
INTRODUCTION Dear customer, thank you for your trust and purchase of our product – the combined boiler ATTACK WOOD&PELLET. The boiler construction is based on the newest knowledge of the biomass combustion and meets all current test criteria and EU directives.
BASIC DESCRIPTION OF THE BOILER The ATTACK WOOD&PELLET is a modern environmentally friendly boiler that saves environment by efficient burning of biomass. The user gets the advantage of low operating costs from wood combustion as well as the convenience of the heating system comparable with gas boilers when burning the pellets.
1.7.1 WOOD In the boiler ATTACK WOOD&PELLET it is possible to burn soft and hard chopped fuel wood with the heat value 15–17 MJ/kg. Particularly suitable is beech, oak, fir, spruce, pine, poplar, alder, willow, birch, ash, wych-hazel, locust, always within the humidity range of 12–20 %. Recom- mended diameter of the wood logs is in the range of 80–150 mm.
1.7.2 PELLETS The pressed wood pellets wihout any additional materials can be burned in the boiler. Parame- ters of the pellets should be following: Approved pellet specification: Measured weight: 600 – 750 kg/m Heat value: 4,7 – 5,0 kWh/kg Size/diameter: 6 mm Size/length: Caution! Max.
2 BOILER ASSEMBLY AND INSTALLATION HANDLING THE BOILER The boiler is delivered on a pallet. Handle it always on the pallet and put it down from the pallet only at the point of installation. This can be done by a manipulation trolley or a crane and lifting eye that is not included into the delivery (recommended specification: lifting screw with an eye M20 ISO 3266, or M20 DIN 580).
2.2.1 BINDING NORMS FOR PROJECTING AND INSTALLATION OF THE BOILERS Installation of the boiler must be done in conformity with the following norms: STN EN 303-5 Heating boilers for solid fuels STN 73 42 10 Manufacture of chimneys STN EN 60 335.1 +A11 Safety of the electrical appliances for household STN EN 12828+A1 Central heating, projecting and installation...
PLACING THE BOILER The boiler is intended for installation and operation in an area conforming to (AA5/AB5) under the STN 33 2000-3. The boiler room must fulfill the above mentioned and the following requirements: • There can be no potentionally explosive environment in the boiler room, as the boiler is not suitable for usage in such environments.
It is not allowed to place the boiler in dwelling premises (including corridors)! BOILER CONNECTION TO THE HEATING SYSTEM The ATTACK WOOD&PELLET must be installed in the system that fulfils the requirements for quality of the heating water: Slovak republic:...
The boiler must be connected with a device regulating the temperature of the boiler´s return connection. It is suitable to use the mixing device Attack-Oventrop (Pic.3), which enables crea- tion of the separate boiler and heating circuit. Thereby is the boiler protected against undercool- ing and the creation of water steam.
2.4.2 CHIMNEY Connection of the appliance to the chimney hole must be always done with in line with local regulations and the appropriate chimney association. The chimney must generate sufficient draught and take the flue gas out into the atmosphere under all operating conditions. Correct dimensions of the chimney are important for correct boiler function, because the burn- ing, output and boiler life-time are influenced by the draught.
LEFT DOOR VERSION There is an option of the ATTACK WOOD&PELLET boiler with the left door (door hinges on the left side). It can be done before the boiler start-up or later, when the boiler is not in service. The main, upper, middle and bottom door can be turned without need of the any additional tools.
Page 16
to be defined by a designer of the heating system according to the system design and local reg- ulations. The electrical installation related to the additional boiler equipment has to be done by a specialist and following the valid regulations. DANGER! The heating system must be equipped with a safety valve against exceeding the pressure in the boiler (2,5 bar).
Page 17
Boiler protection against overheating Every wood gasifying boiler must be fitted with a functional aftercooling circuit. The appropriate valve ensuring this function can be ordered as an accessory. On the pic. 5 you can see the correct installation of the valve of the aftercooling circuit. DANGER! Following the norm EN303-5, the aftercooling circuit against overhetaing must not be used for other purpose than the boiler protection against overheating.
The recommended volume of the accumulation tank for the boiler ATTACK WOOD&PELLET 25 is 2.000 l (the min. volume is 1.250 l). By full load of the hardwood (i.e. 6 hours of operation at full output of 25 kW), the boiler produces 150 kWh of energy.
Page 19
The above mentioned fact is relevant by the operation with WOOD. By the operation with PELLETS it is not relevant, as the boiler does not have to be connect- ed to the accumulation tank, if ONLY PELLETS would be used. Standardly delivered accumulation tanks ATTACK* TUVS —...
• the boiler was operated following the instructions given in this manual and not in the different way. The warranty is valid for a complete boiler ATTACK WOOD&PELLET, except of wearing boiler parts that are usually worn, and therefore they cannot be included into the warranty: •...
Time of operation by max output by wood Volume of water in the boiler Min. volume of accumulation tank 1250 Connection voltage V/Hz/A 230/50/16 The producer, ATTACK, s.r.o. reserves right of technical changes of the products without any previous announcement!
Before starting the operation of the boiler ATTACK WOOD&PELLET for pellets, it is necessary to suck the pellets into the integrated tank manually. Use the TEST mode, by clicking on the „vacu- um suction“.
Page 25
Pic. 7 Description of the main regulation of the boiler The combustion process in the boiler ATTACK WOOD&PELLET is controlled by the modern elec- tronics, equipped with software operating on the basis of the latest knowledge in the field of the biomass burning.
Page 26
Pic. 8 Basic display 1 – Start of boiler, 2 – Boiler temperature, 3 –Flue gas temperature, 4 - Temperature of accumula- tion tank (optional sensor), 5 - Menu settings of parameters, 6 –General settings, 7 – Error messages, 8 – Information menu, 9 – Heating circuit, 10 –Outside temperature (optional sensor), 11 –...
TEST MODE Boiler ATTACK WOOD & PELLET enables to test functionality of some connected electrical devices. Click the button of General settings and then the button TEST for the entry into the Testmode of the boiler (pic. 9, pic. 10).
Page 28
We do the test of devices by clicking the button next to the device or by writing value in % (pic. 11, 12, 13) Pic. 11 Testing activation of devices unable to be changed (modulated) and devices able to be changed (modulated) Pic.
Page 29
Pic. 13 Testing activation of modulated devices CAUTION! After the end of testing of any devices it is always needed to turn off these de- vices. After finishing of the testing come out from test mode with the button of service key. We get into the Main Screen where we again click on service key and there on button OFF (see pic.
Page 30
Pic. 15 Coming out from Test menu 2 Pic. 16 Coming out from Test menu 3...
BOILER’S OPERATION The boiler ATTACK WOOD&PELLET is one of combined boilers where after burning the wood out it is not needed to make an intervention into the boiler for burning the pellets. The boiler auto- matically detects the burning-out of the wood and, if required for further heat production, starts the pellet combustion in the pellet section.
Page 32
We start the boiler by pushing the button START. There will be displayed Main Screen where we can choose among three types WOOD, PELLET, COMBI (pic. 17 and 18): Pic. 17 Starting the boiler Pic. 18 Start Options Start Options: WOOD –...
7.3.1 OPERATION WITH WOOD Use this mode, if: You wish to operate the boiler as a WOOD gasifying boiler. When the WOOD is burned out in the feeding chamber, the boiler is stopped (the pellet part will not be automatically started to work). The ways to light the boiler up: •...
Page 34
Pic. 20 Choosing type of ignition 7.3.1.1 MANUAL LIGHT UP OF WOOD 1. Turn the main switch on, if it has not been done yet. 2. Open the main door and the door of the feeding chamber. Check the level of ash in the feeding chamber.
Page 35
4. Put the paper or cardboard (the best material), rolled into tubes (Pic. 11). If there are cinders on the bottom of the feeding chamber, put the paper or the cardboard on them. Pic. 21 Preparation for lighting up the wood 5.
Page 36
Pic. 22 The way to prepare the wood for lighting up Pic. 23 Loading the full chamber 6. Close the upper and the bottom door, manually light up through the middle door only. 7. Click on button START (pic. 24)
Page 37
Pic. 24 Starting the boiler 8. There will be displayed Start Options where you choose the option WOOD (pic. 25) Pic. 25 Choosing WOOD mode...
Page 38
9. After choosing WOOD mode there are displayed Start Options where we choose manual ig- nition (pic. 26). The exhaust fan will start to work and the wood will be prepared for lighting Pic. 26 Lighting up the wood in the wood gasification part: 1 - manual starting (ignition), 2 - automatic starting, 3 –...
Page 39
Pic. 27 Displaying WOOD operation All operational information are displayed in information menu. You get into information menu by clicking on button "i". Pic. 28 Entry into information menu Immediately after firing up the boiler is in Ignition phase (pic. 29).
Page 40
Pic. 29 Ignition phase When the temperature rises, the boiler comes into the Pre-Heating phase (pic. 30). CAUTION! Pre-Heating phase - phase coming when the flue gas temperature rises dur- ing the set time in parameters. If the flue gas temperature rises during another time set in parameters the boiler crosses into Control phase.
Page 41
Pic. 31 Regulation phase Once the boiler reaches set temperature and exceeds it, then there comes Glow (Ember) Protec- tion phase pic. 32) Pic. 32 Glow (Ember) Protection phase CAUTION! If the flue gas temperaturewill not rise in 30 minutes, there is written the lack of fuel In case you decide to turn off the boiler it is needed to wait until the fuel will burn out.
Page 42
Pic. 33 Mode selection There will be displayed message that the burning has already started if you really want to stop. Then confirm that you really want to turn the boiler off (pic. 34). Pic. 34 Turning the WOOD mode off...
Page 43
7.3.1.2 AUTOMATIC LIGHT-UP OF WOOD The wood can be automatically ignited by pellets, with no need to prepare the lighting-up with paper, nor cardboard. However, it is necessary to use the wood of small diameter (wood chips of 20×20 mm). CAUTION! The automatic light-up of the wood is a complicated process and the first trial requires the attention of the customer.
Page 44
Pic. 36 Loading the wood into the chamber by the automatic light-up Pic. 37 Loading the full chamber 3. Close all door (upper, middle, bottom, main ones). 4. Click on button START (pic.38).
Page 45
Pic. 38 Boiler starting 5. There will be displayed Start Options where you choose the option WOOD (pic. 39) Pic. 39 Choosing WOOD mode 6. After choosing WOOD mode there are displayed Start Options where we choose automatic ignition (pic. 40). Before the automatic ignition choose its parameters. The exhaust fan will start to work and the wood will be prepared for lighting up.
Page 46
Pic. 40 Choosing the automatic ignition 1 - manual starting (ignition), 2 - automatic starting, 3 – time of glowing the heating coil (by au- tomatic ignition) , 4 – delay timeof ignition (by automatic ignition), 5 – output the ignition coil works on (by automatic ignition) The amount of power with which will be ignited the wood by the pellet section should be well considered.
Page 47
Pic. 41 Display after activation of automatic ignition of wood Immediately after starting of the boiler it is in the Pre-Flushing phase (pic. 42). Pic. 42 Pre-Flushing of the burner After Pre-Flushing of the burner there comes the phase of Filling the pellets into the burner (pic. 43).
Page 48
Pic. 43 Phase of Filling the pellets into the burner After Filling the pellets into the burner there comes the phase of Ignition (pic. 44) Pic. 44 Phase of Pellet Ignition CAUTION! In case of unsuccessful ignition there comes Ignition no. 2. It is possible to set the number of repeated ignitions in parameters.
Page 49
Pic. 45 Pre-Heating phase After Pre-Heating of pellets there comes the phase of Regulation of pellets (pic. 46). Pic. 46 Regulation of pellets phase After the phase of Regulation of pellets the burner shuts down and there comes Pre-Heating of wood (pic.
Page 50
Pic. 47 Pre-Heating of wood Once the flue gas temperature rises the Regulation mode comes (pic. 48). Pic. 48 Regulation mode CAUTION! If the flue gas temperature does not rise above 90 ° C during 5 minutes during the regulation, the boiler will report a fuel shortage (pic. 49). If the flue gas temperature does not rise above 90 °...
7.3.2 DESCRIPTION OF THE MAIN CONTROL MODES The pellet operating mode is a fully automatic mode capable of burning PELLETS. Use this mode when: • You want to operate the boiler only with pellets CAUTION! For functionality of operation with PELLETS it is needed to have activated timer for the days you want to heat with pellets.
Page 53
Pic. 52 Choosing operation mode PELLETS After choosing the PELLET mode the boiler is automatically switched on. Click on Information menu, there you can see all operational information (pic. 53). Pic. 53 Displaying operational information 2. Then the mode of Pre-flushing of the burner comes (pic. 54) where the electronics checks if the pellet tank sucked pellets.
Page 54
Pic. 54 Mode of Pre-flushing 3. After Pre-flushing there is the mode of pellet filling into the burner (pic. 55) and pellet’s igni- tion (pic. 56). Pic. 55 Mode of Filling of pellets into the burner...
Page 55
Pic. 56 Mode of pellets’s ignition CAUTION! In case of unseccusseful ignition there comes Ignition no. 2. It is possible to set the number of repeated ignition in advanced boiler’s parameters. 4. After pellet ignition there comes Pre-Heating phase (pic. 57) Pic.
Page 56
Pic. 58 Regulation mode Boiler shutdown options are: 1. When the boiler temperature is reached or exceeded 2. When the accumulation tank temperature is reached (if there are installed sensors in accumu- lation tank) 3. By boiler’s timer 4. By room thermostat 5.
Page 57
Pic. 60 Boiler shutdown from the reason the accumulation tank temperature is reached - 1 Pic. 61 Boiler shutdown from the reason the accumulation tank temperature is reached - 2 6. After burning the burner will be cleaned and shut down, the boiler remains in standby mode and waits for further switching on according to temperatures.
7.3.3 COMBINED OPERATION MODE The combined operation mode is a fully automatic mode that is able to operate the WOOD burning or the PELLET burning, but not both at the same time CAUTION! For automatic switching the operation from wood to pellets in COMBI mode it is needed to have activated timer for the days you want to heat with pellets.
Page 59
Pic. 63 Choosing COMBI mode The combined mode can start with burning the wood or burning the pellets. It is not possible to burn both fuels (i.e. the wood and the pellets) at the same time. After choosing COMBI mode it is needed to choose the ignition between manual and automatic (pic.
before it starts to burn pellets. The operation with pellets can be anytime interrupted (the pellets must automatically burn down in the burner) and the wood can be loaded and burned. CAUTION! ATTENTION! It is not allowed to put any flammable materials or objects into the loading chamber of the boiler during the operation with pellets.
Page 61
Pic. 66 Window 1, Information The first page – the “Information 1” – gives the basic information about the boiler state: boiler, temperature, flue gas temperature, actual value of the oxygen in the flue gas, presence of the flame in the combustion chamber – the photocell, cycle of the pellet feeding and duration of the feeding in one cycle) Pic.
Page 62
The second page – the “Information 2” – displays the actual output of the exhaust ventilator and the burner ventilator, actual rotations of the burner ventilator, position of the primary and sec- ondary flap serving to control the wood gasification process (Pic. 23). Pic.
9 SETTING THE PARAMETERS The boiler ATTACK WOOD & PELLET enables to set general settings for correct boiler’s operation like boiler’s temperature, flue gas temperature, temperature of heat pump’s starting etc. (pic. 69). Pic. 69 Entry to parameter’s settings Pic. 70...
Page 64
Parameters description: Boiler temperature – set temperature which should be reached Start boiler pump – the temperature when the pump is switched on Pump delay – the time of pump delay how long the pump will be running after boiler’s shut down Maximum Power –...
Page 65
Pic. 72 Displaying setting of sensors’s in accumulation tank temperature There will be displayed table with the settings of accumulation tank’s control (pic. 73). Pic. 73 Setting of accumulation tank...
Middle sensor Limit - OFF- the temperature above which the temperature of the middle sensor rises in the accumulation tank, the boiler switches off 10 SPECIAL SETTINGS Boiler ATTACK WOOD & PELLET enables to set General settings. For displaying General settings click on Service key (pic. 74). Pic. 74...
Page 67
Pic. 75 Displaying General Settings 1 – language selection, 2 – internet connection, 3 - saving and loading settings, 4 – service set- tings (accessible only after entering the code), 5 – timer settings, 6 – TEST MODE Set the time / date– it is possible to set the exact time and date. If the boiler will disconnect. If the boiler is disconnected from the power supply or the electrical supply of the boiler falls out for some reason, it can keep the time and date for about 3 days.
11 INTERNET CONNECTION The boiler can be connected to the internet by the LAN and it can be regulated through the re- mote control. The control is available via the local network and via internet as well. It is necessary to have the IP address from the internet provider to have an access from internet.
Page 69
Mocha VNC Lite Destination port: 5900 Password: attack The boiler can also be controlled and accessed via a computer, via program: VNC Viewer (napr. UltraVNC) WARNING! If you have set up automatic IP address assignment via DHCP in the router,...
12 TIMER SETTINGS Timer enables to set exact times in days of heating with mode PELLETS or COMBI in operation for pellets. For displaying boiler’s timer click on service key and then on symbol of timer (pic. 80). If the timer is not activated in PELLET mode the boiler will not start up. The timer is activated from the factory.
- insert the USB stick with the software into the boiler display - switch on the boiler with the main switch and wait - the ATTACK logo appears on the display, followed by a black screen with white com- mands - at the end of the installation, "Please select USB (Boot reboots)"...
14 FACTORY SETTINGS AND FILES LOADING If the boiler malfunction has occurred and the boiler is in a state where it is not possible to re- move the malfunction or to select the desired boiler mode, the boiler must be restartedť. We enter into General settings and click on floppy disk of the boiler (pic.
Boiler_log.xls and Boiler_log_old.xls). We can then analyze the operation of the boiler from the day and the day before you have used the boiler. 15 FAULTS OF THE BOILER ATTACK WOOD & PELLET Damage of lambda probe The boiler must heat the lambda probe after starting of heating and the probe must show 21% oxygen within 3 minutes.
17 BOILER CLEANING To ensure the correct boiler operation and the appropriate comfort and life, it is necessary to clean it regularly. CAUTION! Always clean the boiler regularly and properly, otherwise it my cause de- creased boiler life or wrong burning. If the boiler is not cleaned regularly and suffi- ciently, the warranty is not valid.
18 ASSEMBLY AND DISSASSEMBLY OF THE REFRACTORY ITEMS The estimated lifetime of the refractory pieces is the same as the lifetime of the boiler. Thereby it is not necessary to disassembly them for exchange, if they are not damaged. Pic. 86 Assembly and disassembly of the refractory pieces On the pic.
19 TABLE OF RELATION OF THE RESISTANCE AND THE TEM- PERATURE OF THE SENSOR PT 1000 The characteristics relates to the boiler temperature sensor and to the flue gas temperature sen- sor as well: Temperature [0C] Resistance [Ω] 1 000 1 039 1 077 1 116...
20 ELECTRICAL CONNECTION SCHEME Description of the electrical scheme: CL – motor of the burner cleaning FL – flap of the air inlet into the burner HS – ignition coil F – female M – male FAN – ventilator of the burner HALL –...
21 OVLÁDANIE AUTOMATICKÉHO KOTLA The boiler enables to control switching on of the automatic boiler after burning all fuel out wit- hout the installation of additional modules. The condition of automatic boiler start function is the temperature sensors in the accumulation tank are correctly installed. For activation of starting function of the boiler click on symbol of heating circuit (pic.
Page 82
Pic. 88 Basic description of Heating circuit To enable the automatic boiler start function, click the boiler symbol (Pic. 49 where you can see the parameter table (Pic. 90). Pic. 89 Click for activation of automatic boiler’s function...
Room thermostat can be connected to the boiler. 22 ACCESSORIES The ATTACK WOOD&PELLET boiler is delivered functionally tested, packed and placed on a wooden pallet. The following accessory items are delivered: • Instruction manual •...
23 INSTRUCTIONS FOR DISPOSAL OF THE APPLIANCE AFTER ITS LIFETIME ENDS Ensure the disposal of the appliance (boiler) by the waste disposal service, eventually use the regulated waste dump, controlled by the municipal authority. 23.1 DISPOSAL OF PACKAGING Dispose the packaging by the waste disposal service, eventually use the regulated waste dump. 24 SERVICE PARAMETERS SETTINGS A service code is required to set service parameters.
Page 85
Pic. 92 Entry into Service parameters Pic. 93 Access to Service parameters After entering the service technician's access code, the advanced boiler parameters are made available.
Page 87
Boiler temperature – the boiler should reach this temperature. Start boiler pump - the pump will be switched on after reaching this temperature Pump delay – pump off time after boiler shutdown Maximum power of burner - determines the output of the burner Exhaust-fan maximum power - determines the maximum output of the exhaust fan Exhaust-fan minimum power - determines the minimum output of the exhaust fan Exchanger cleaning worktime - is tme that the exchanger will be cleaned by turbulators...
Page 88
Pic. 96 Service parameters, page 3 Photocell Fier off – if the value of the flame intensity in the burner drops below this value, the boiler evaluates that the flame has been lost in the burner, i.e. the process of burning is stopped. The boiler evaluates this as an error Difference boiler temperature Start - determines how many degrees the boiler temperature must fall below the set temperature so that the boiler is switched on again (only in PELLET...
Page 89
Pic. 97 Service parameters, page 4 Feeding time at 100% power - is the part of the cycle during which pellets will be delivered to the burner Protection of burner fan - when this function is activated the boiler checks the functionality of the pellet fan, shuts it down in the event of a malfunction or clogging and shows an error Pellet-Fan during ignition - it can only be set by the manufacturer or the service organization it is the burner fan power that will be during the burning time after ignition...
Page 90
Pic. 98 Service parameters, page 5 Number of suction retries – the number of suction repeats in failed attempts Turbine max runtime - determines how long a vacuum fan will suck in pellets without a break Turbine rest time- determines how long the turbine will have a pause in suction after which it will be switched on again Power regulator worktime –...
Page 91
Pic. 99 Service parameters, page 6 Upper sensor Limit - ON - is the temperature below which the upper sensor temperature of the accumulation tank must decrease to switch the automatic boiler on Middle sensor Limit - OFF - is the temperature which when the middle sensor of the accumula- tion tank reaches the automatic boiler switches off Difference boiler temp.
Page 92
Pic. 100 Service parameters, page 7 Secondary- Airflap Min. Open - the minimum opening of the secondary flap Secondary- Airflap Ignition - the flap position that will be set when the wood is ignited Secondary- Airflap Pre-Heating - the position of the secondary flap that will be set when the boiler is in Pre-Heating phase Ignition max.
Page 93
Pic. 101 Service parameters, page 8 Primary-Airflap Autom. Ignition – can only be set by the manufacturer or service organization, the primary flap position that will be set during automatic wood ignition with pellets Secondary-Airflap Autom. Ignition – can only be set by the manufacturer or service organiza- tion, the secondary flap position that will be set during automatic wood ignition with pellets Oxygen setpoint max.
25 THE ORIGINAL ES DECLARATION OF CONFORMITY POZ-027/041017 I, Rudolf Bakala, the corporate representative of the ATTACK, s.r.o. company, declare, that the products mentioned below fulfil requirements of the technical prescriptions, under conditions specified for using they are safe, they are produced in conformity with technical documentation and with the norms and regulations given in this document.
Page 95
In case of any questions related to the processing of your personal data, please do not hesitate to contact us at tel. no. 00421 43 400 3131 or support@attack.sk. Privacy Manager: ATTACK, s. r. o., with its registered office at Dielenská Kružná 5020, 038 61 Vrútky, Slovak Re- public Tel .: +421 43 4003 101 Fax .: +421 43 3241 129...
Page 96
your personal data, i. e. direct offer of our products sent to you. 2) The legal basis for fulfilling the extended warranty agreement on the product in which you enter the Boiler Startup Record whereare your personal data is Art. Article 6 1. Letter. (f) Regulation (EU) 2016/679 of the European Parliament and of the Council of 27 April 2016 on the protection of natural persons with regard to the processing of personal data and on the free movement of such data, and repealing Directive 95/46/EC (General Data...
Page 97
ATTACK, s. r. o., Dielenská Kružná 5020, 038 61 Vrútky, Slovak Republic. In the objection, it is suf- ficient to provide the name, address and the text "I hereby raise an objection to the processing of my personal data for the purposes of direct marketing"...
Page 100
All provided information is temporary, subject to change without notice and for informational purposes only. Variations in product visual display are possible and may not match the offer and range of equipment for different markets. ATTACK s.r.o. reserves the right to make changes to specifications and content without prior notice. Pictures and product specifications are...