If there is a danger of approach of inflammable (explosive) gases or fumes to the boiler (e.g. by
PVC application), it must be put out of operation early including the burning flame (EKO, PLQ, P).

sAfETy COnDITIOns

When installing a boiler, a safe distance of its surface from inflammable materials depending on
the degree of flammability must be kept. Distances:
y
from inflammable materials of B, C1, C2 categories
y
from inflammable materials of C3 category
y
from materials not tested by STN 73 0853
ExAMPLEs Of CLAssIfICATIOn Of ThE buILDInG MATErIALs by ThE InfLAM-
MAbLE LEVEL:
y
A category non-combustible (brick, blocks, concrete, tiles, mortar, plaster)
y
B category very difficult to ignite (heraklit, lignos, basalt boards)
y
C1 category difficult to ignite (beech, oak, wood-fibre, werzalit, cardboard)
y
C2 category normally flammable (pinewood, solodur)
y
C3 category easily flammable (wood-fibre boards, polyurethan, PVC, styrofoam)
If a boiler stands on the floor made from flammable materials, it must be protected by incombus-
tible insulating plate exceeding boiler dimensions for at least in 150 mm. Solid materials of the A
category can be used as incombustible and insulating materials. Objects from flammable materials
cannot be placed on the boiler nor in the distance shorter than 500 mm.

COnDITIOns TO KEEP ThE ECOLOGICAL PArAMETErs

The boiler is set up and tested by the producer to ensure the optimum process of burning in line
with the ecological requirements. The boiler must be installed into the dry and dustless environ-
ment, without possibility to suck strange, aggressive materials or fogs through the air supply. Ask
the specialized company to take care about the the flue gas exhaust. It is necessary to make the
annual tests and cleaning.

TEChnICAL DEsCrIPTIOn EKO, PLQ, KLV, KLQ, E, EZ, P TyPEs:

The body of boilers consists of cast-iron elements with the system of exchanger ribs, where the
flue gas go into the collector and through draught breaker into the chimney. The pipes with screw
joints 1" or 6/4" (S, P) have to be connected to the heating system on the rear side of the body. In the
upper front in a copper sleeve there are emergency thermostat and sensors of boiler thermostat
and thermomanometer. In the rear bottom part there is the inlet and outlet valve and in the front
upper part there is a reverse valve with a sensor of the pressure gauge.
The boiler body is insulated by insulating material preventing the heat leakage into surround-
ings. The front wall is covered by protective metal sheet. After demounting the boiler skeleton and
draught breaker, it is possible to get to the combustion chamber, to check or to clean the exchang-
CAST IRON FLOOR STANDING GAS BOILER