Technical Specifications Of The Cpv Valve Terminal With; Index; Direct Link Type Cpv..-Ge-Dn-8 - Festo CPV Series Manual

Compact performance cpv valve terminal with direct link
Hide thumbs Also See for CPV Series:
Table of Contents

Advertisement

A. Tecnical data and Index
A.2 Technical specifications of the CPV valve terminal with

direct link type CPV..-GE-DN-8

General
Temperature range:
– operation
– storage/transport
Relative humidity
Protection class as per EN 60 529
Connector plugged in or fitted with
protective cap
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204-1 / IEC 204)
Valves
Load voltage of
solenoid valves on CPV valve terminal
Pin 2
Load voltage connection
– rated value
– tolerance
Current consumption
• pin 2
Residual ripple
Bridging time during logic voltage failure
A-16
o
o
- 5
C ... + 50
C
o
o
-20
C ... + 70
C
95 %, non-condensing
IP 65
by means of PELV power units
(protected extra low voltage)
see Pneumatics manual
type P.BE-CPV-...
24 V DC
21.0 ... 26.4 V
Sum of all switched-on CPV solenoid
valves; see manual "CPV valve terminal,
Pneumatics"
4 Vpp (within tolerance)
20 ms
CP-DN8 9806NH