5. Conversion and maintenance
5.4
Converting the MPA−F valve terminal
5.4.1 Conversion to different pressure zones
Pressure zones
Tab. 5/6: Number of pressure zones
Festo P.BE−MPAF−EN en 0804NH
The following conversion work can be undertaken on the
MPA−F valve terminal:
Conversion of the MPA−F valve terminal to different pressure
zones
Adding valve positions (manifold blocks)
Basic information on pressure zone separation is provided in
chapter 1, section Pressure zone separation".
The MPA −F valve terminal can be fitted with the following
number of pressure zones depending on the connection vari
ant:
Electrical connection variants of the valve terminal
CPX terminal
1 ... 16
The pressure zones are formed by using either special mani
fold blocks or special separating seals (see chapter 1, section
Pressure zone separation").
The following section describes the formation of pressure
zones by using separating seals.
For converting the valve terminal, you will require the follow
ing components for each pressure zone:
Separating seal with pressure zone separation
(see chapter 1, Fig. 1/9)
MPM connection
1 ... 12
5−25