Incorrect Date And Time; Drives Reported As "Dead" When Starting System; Added Drive Reported As Defective - Fujitsu PRIMERGY RX600 S3 SAS Operating Manual

Hide thumbs Also See for PRIMERGY RX600 S3 SAS:
Table of Contents

Advertisement

Incorrect date and time

7.6
Incorrect date and time
Ê Set the date and time in the operating system or in the BIOS Setup under the
Main menu, using System Date and System Time respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under Linux,
and would overwrite the system time in the default setting on shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the Technical
Manual for the D2630 system board) or contact our customer service team.
7.7
Drives reported as "dead" when starting
system
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
7.8

Added drive reported as defective

RAID controller is not configured for new drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched on.
If the drive continues to be reported as defective, then replace it (see section
"Installing/removing HDD/dummy unit" on page
74
82).
Operating manual