NOTE:
Resetting the IPSI will terminate the administration session. If further administration is
required initiate a new telnet session to the IPSI.
13
Check the LCD. Verify that it has an I P with a filled-in V showing at the bottom. (See
"IP Server Interface
14
If logged into the IPSI type quit to logoff the IPSI.
Disconnect the laptop from the faceplate.
15
NOTE:
Always use the arp -d 192.11.13.6 command (see step four) to clear the ARP cache on the
laptop before connecting to another IPSI. If the cache is not cleared the laptop will appear
to 'hang' and will not connect to the next IPSI.
16
Repeat for each IPSI circuit pack.
Verify connectivity to the media servers
The following procedure is performed from both ASA and the S8700 Media Server Web
Interface while connected to the active media server.
1
From ASA type list ipserver-interface and press
Verify that all ISPI circuit packs are translated.
•
2
From the S8700 Media Server Web Interface under Diagnostics click on Execute
Pingall. Select Other Server(s), All IPSIs, Ethernet switches and click on Execute
Pingall.
Verify that all endpoints respond correctly.
Verify IPSI firmware version
1
From the S8700 Media Server Web Interface under Installation and Upgrades click on
View IPSI Version. Select Query All and click on the button View IPSI Version.
LEDs")
CLK
S
E
R
V
October 2002
Connect the Hardware
Enter
211