Example 4-Pair Labeling to Information Outlet
Figure notes
Equipment Room
1
2
To Central Location for Terminals 1
through 6
3
Blue Row on 110 Terminal Block
Purple Row on 110 Terminal Block
4
To Port Connector on Media Gateway
5
(Media Gateway 1, Carrier A, Slot 03)
Label Expansion Control Carrier Cable
1
Place the appropriate AUX connector label on the assigned 110-type terminal block row.
On the expansion control carrier cable, place a yellow auxiliary label on the connectors
2
at each end of the cable.
3
Write "AUX" on each label.
Connect Expansion Control Carrier Outputs Cable
''Installing the Telecommunications Cabling'' on page 142
Patch Cord/Jumper Installation and Administration
258A Adapter
6
7
D-Inside Wire Cut Down to
Connecting Block
8
Information Outlet
Voice Terminal
9
October 2002
177
crdf4pr CJL 102996