Station Circuit Distribution from
Equipment Room
This section explains the station circuit distribution from the equipment room to the information
outlets for new wiring installations. Example connection diagrams are provided to show the
options for running and connecting the station cables.
If most of the telephones/voice terminals that require remote powering are within 250 ft (76.2
m) of the equipment room, 4-pair station circuits are run from the equipment room to the
information outlets. If this is not the case, or if the customer requires 2-point administration,
3-pair station circuits are run from the equipment room to satellite locations. Then, the 4-pair
station circuits are run from the satellite locations to the information outlets.
This section has information about
''4-Pair Station Circuits'' on page 165
''3-Pair to 4-Pair Station Circuit Distribution'' on page 165
Lists of terminals that can be connected to the S8700 Multi-Connect configuration are provided
in
''Voice and Data Terminals'' on page 170
''Administration Terminals'' on page 172

4-Pair Station Circuits

Four-pair circuits can be run directly from an equipment room MDF to a 258A or BR2580A
adapter as shown in
station cables connect the adapter to the information outlets.
The 4-pair station cables can be run directly from the equipment room to the information outlets
if 4-pair terminal blocks are used in the distribution field. See
or Satellite Location'' on page
terminal blocks.
If 110-type terminal blocks are used with a modular plug-ended station cable, an adapter can be
connected directly to the 110-type terminal block connectors. See
Room or Satellite Location'' on page

3-Pair to 4-Pair Station Circuit Distribution

''3-Pair to 4-Pair Satellite Location Connectivity'' on page 168
distribution from an equipment room MDF to a satellite location using 110-type hardware.
Four-pair circuits are distributed from the satellite location to the information outlets.
''4-Pair Circuit Distribution and Connectivity'' on page
167. The station cables must be field-terminated on the 110-type
167.
October 2002

Station Circuit Distribution from Equipment Room

''4-Pair Run to Equipment Room
''4-Pair Run to Equipment
shows the 3-pair circuit
165
166. The 4-pair