Resolve Alarms; Led Indicators - Avaya S8700 Installing Manual

With media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

318
Testing the Complete Configuration
2
Type 3 in the stratum field.
3
Type the port network number where the TN780 Tone-Clock circuit packs reside in the
port network field.
NOTE:
Wait 1 minute for the software to reconfigure the media server synchronization.
4
Verify the results of test 649. If test 649 fails with a code of 2101, then check the wiring
for EXTSYN0 and EXTSYN1. Refer to the maintenance book for your configuration
If test 649 is successful, then the media server is getting correct timing from the Stratum 3
clock.

Resolve Alarms

As a last step, inspect the alarms log.
Use the media server Web interface.
Click on View Current Alarms and see if any alarms were generated. If so, resolve any
1
alarms that may exist using the maintenance book for your configuration

LED Indicators

Refer to the maintenance book for your configuration
If a maintenance object begins to fail some periodic tests, the media server will generate an
alarm. The media server identifies 3 levels of alarms:
Major Alarms
immediate attention.
Minor Alarms
critical portion of the configuration to be inoperable. This condition requires action, but
its consequences are not immediate. Problems might be impaired service to a few trunks
or stations or interfering with one feature across the entire configuration.
Warning Alarms
in equipment external to the configuration. Warning alarms are not reported to the
attendant console or INADS.
Alarms are communicated to users and technicians by entries in the alarm and sys logs and the
lighting of LEDs located on the attendant console, on all circuit packs, and, optionally, on
customer-designated telephones.
More detailed information is available here for:
"S8700 Media Server LEDs"
"Avaya Ethernet Switch LEDs"
"UPS LEDs"
Failures that cause critical degradation of service and require
Failures that cause some degradation of service, but do not cause a
Failures that cause no significant degradation of service or failures
October 2002
for detailed alarm and LED descriptions.
.
.
.