License - Siemens SCALANCE W1780 Configuration Manual

Industrial wireless lan
Table of Contents

Advertisement

● Firmware on PLUG
When enabled, the firmware will be stored on the PLUG. This means that automatic
firmware updates/downgrades can be made with the PLUG. The box
"Info" shows whether or not the firmware is stored on the PLUG.
● Modify PLUG
Select the required setting from the drop-down list. You have the following options for
changing the configuration on the PLUG:
– Write current configuration to PLUG
– Erase PLUG to factory default
Procedure
Requirement:
● User with administrator rights
Modifying the PLUG configuration
1. Select the required option from the "Modify PLUG" drop-down list.
2. Click the "Set Values" button.
6.5.18.2

License

NOTICE
Do not remove or insert the PLUG during operation.
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether a PLUG is inserted at one second intervals. If it is detected that the
PLUG was removed, there is a restart.
If a valid PLUG was inserted in the device, the device changes to a defined error state
following the restart. With SCALANCE W, the available wireless interfaces are deactivated in
this case.
If the device was configured at one time with a PLUG, the device can no longer be used
without this PLUG. To be able to use the device again, reset the device to the factory settings.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
This option is available only if the status of the PLUG is "NOT ACCEPTED" or
"FACTORY".
The configuration in the internal flash memory of the device is copied to the PLUG.
Deletes all data from the PLUG and performs low-level formatting.
Configuring with Web Based Management
6.5 "System" menu
213