File upload via HTTP(S): validation of FileType
<file type> FAILED
File upload via TFTP: load of FileType <file type>
OK
→ restart required
File upload via TFTP: load of FileType <file type>
OK
File upload via TFTP: validation of FileType <file
type> IDENTICAL
File upload via TFTP: validation of FileType <file
type> FAILED
File upload via TFTP: file transfer of FileType <file
type> FAILED
File upload via TFTP: file transfer of FileType <file
type> failed. Cannot connect to given IP address
File download via TFTP: file transfer of FileType
<file type> failed. Cannot connect to given IP ad‐
dress
Messages error status
Messages
New Fault state:<fault description>
<fault description>:"Warm start performed."
"Cold start performed." "Link down on P1." "Link
up on P1." "Power down on line L1 (L2)" "DFS: No
channels are available at WLAN2"
Fault state gone: <fault description>
<fault description>:"Warm start performed."
"Cold start performed." "Link down on P1." "Link
up on P1." "Power down on line L1 (L2)" "DFS: No
channels are available at WLAN2" "PLUG not ac‐
cepted. See System PLUG mask for details."
New Fault state (reconfiguration): <fault descrip‐
tion>
<fault description>:"Link down on P1." "Link up on
P1." "Power down on line L1 (L2)"
Fault state gone (reconfiguration): <fault descrip‐
tion>
<fault description>:"Link down on P1." "Link up on
P1." "Power down on line L1 (L2)"
Fault state: <fault description> cleared.
<fault description>:"Warm start performed" "Cold
start performed".
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
Description
Loading the file via HTTP(S) failed. The file contains errors or is invalid.
Loading the file using TFTP was successful. A restart is required.
Loading the file using TFTP was successful.
Loading the file using TFTP was successful. The file is identical to the
existing file.
Loading the file using TFTP failed. The file contains errors or is invalid.
Loading the file using TFTP failed. The file name is incorrect or the file
does not exist on the server.
Loading the file using TFTP failed. The TFTP server cannot be reached
or the settings are incorrect.
Saving the file using TFTP failed. The TFTP server cannot be reached or
the settings are incorrect.
Description
You configure the events in "System > Events".
You configure the monitoring of the power supply and the link on the
Ethernet port in "System > Fault Monitoring".
Incoming fault.
Not all events automatically lead to a fault. On the "Events" WBM page,
you specify which events will be logged, for example device restart,
changed link on the Ethernet port.
Outgoing fault
Incoming fault.
The event was triggered due to a change in the configuration.
Outgoing fault.
The event was triggered due to a change in the configuration.
Fault was acknowledged by the user.
Appendix D
D.1 Messages in the event log
351