● User Name
If necessary, enter the user name used for authentication on the SMTP server.
● Password
If necessary, enter the password used for authentication on the SMTP server.
● Password Confirmation
Repeat the password.
● Port
Enter the port via which your SMTP server can be reached.
Factory settings:
– 25 (None)
– 465 (SSL/TLS and StartTLS)
● Security
Specify whether transfer of the e-mail from the device to the SMTP server is encrypted. This
is only possible when the SMTP server supports the selected setting.
Note
2-factor authentication (2FA)
2-factor authentication is not supported.
– SSL/TLS
– StartTLS
– None: The e-mail is transferred unencrypted.
● Test
Sends a test e-mail to the configured recipients.
● Test Result
Shows whether the e-mail was sent successfully or not. If sending was not successful, the
message contains possible causes.
Procedure
Configuring the SMTP server
1. Enable the "SMTP Client" function.
2. Enter the IP address or the FQDN of the SMTP server for "SMTP Server Address".
3. Click the "Create" button. A new entry is generated in the table.
4. Enter the name of the sender that will be included in the e-mail for "Sender Email Address".
5. Enter the user name and password if the SMTP server prompts you to log in.
6. Under "Security", specify whether transfer to the SMTP server is encrypted.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management