Siemens SCALANCE W1780 Configuration Manual page 197

Industrial wireless lan
Table of Contents

Advertisement

Description
The page contains the following boxes:
● SNTP Client
Enable or disable automatic time-of-day synchronization using SNTP.
● Current System Time
Shows the current date and current normal time received by the device. If you specify a time
zone, the time information is adapted accordingly.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place.
● Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
– Manual
– SNTP
– NTP
– SIMATIC
● Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
The time in the "Current System Time" box is adapted accordingly.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
The time was not set.
Manual time setting
Automatic time-of-day synchronization with SNTP
Automatic time-of-day synchronization with NTP
Automatic time-of-day synchronization using the SIMATIC time frame
Configuring with Web Based Management
6.5 "System" menu
197