● SNMPv3 User Migration
– Enabled
– Disabled
● SNMP Engine ID
Shows the SNMP engine ID.
● SNMP Agent Listen Port
Specify the port at which the SNMP agent waits for the SNMP queries.
Procedure
1. Select the required option from the "SNMP" drop-down list:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
2. Enable the "SNMPv1/v2c Read Only" check box if you only want read access to SNMP
variables with SNMPv1/v2c.
3. Enter the required character string in the "SNMPv1/v2c Read Community String" input box.
4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String"
input box.
5. If necessary, enable the SNMPv3 User Migration.
6. Click the "Set Values" button.
See also
Technical basics (Page 33)
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
If the function is enabled, an SNMP engine ID is generated that can be migrated. You can
transfer configured SNMPv3 users to a different device.
If you enable this function and load the configuration of the device on another device,
configured SNMPv3 users are retained.
If the function is disabled, a device-specific SNMP engine ID is generated. To generate
the ID, the agent MAC address of the device is used. You cannot transfer this SNMP user
configuration to other devices.
If you load the configuration of the device on another device, all configured SNMPv3
users are deleted.
Configuring with Web Based Management