6.10 "Security" menu
● Dot1X Server Certificate
Specify whether or not the RADIUS server identifies itself to the client using a certificate.
● Dot1x EAP Types
Specify the authentication methods. The following methods exist:
– Auto
– EAP-TLS
– EAP-TTLS
– PEAP
Procedure
1. Enter the necessary values in the input boxes.
2. Select the required entry in the "Dot1x EAP Types" drop-down list.
3. Click the "Set Values" button.
6.10.4.6
802.11r
On this WBM page, you configure the setting for Fast BSS Transition.
Note
This WBM page is only available in access point mode.
You can find additional information under "Description > IEEE 802.11r".
320
Client offers RADIUS server all methods.
Extensible Authentication Protocol - Transport Layer Security
Uses certificates for authentication.
Extensible Authentication Protocol - Tunnel Transport Layer Security
After setting up the TLS tunnel, MS-CHAPv2 is used for internal authentication.
Protected Extensible Authentication Protocol
Alternative draft protocol of IETF for EAP-TTLS
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03