Configuring with Web Based Management
6.5 "System" menu
● Type of notification
– E-mail
– Trap
– Log Table
– Syslog
– Error
Procedure
Follow the steps below to change entries:
1. Select the check box in the row of the required event. Select the event in the column under
the following actions:
– E-mail
– Trap
– Log table
– Syslog
– Error
2. Click the "Set Values" button.
168
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP Client" function is enabled.
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
The device writes an entry to the event log table. The content of the event log table is
displayed in "Information > Log Tables > Event Log".
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog Client" function is enabled.
The device triggers an error. The error LED lights up and the currently pending error is
displayed under "Information > Faults".
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03