Siemens SCALANCE W1780 Configuration Manual page 262

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.7 "Layer 2" menu
Description
The page contains the following boxes:
● Base Bridge mode
Select the required mode from the drop-down list. The following modes are possible:
Note
Changing Base Bridge mode
Note the section "Changing Base Bridge mode". This section describes how a change
affects the existing configuration.
– 802.1Q VLAN Bridge
– 802.1D Transparent Bridge
● VLAN ID
Enter the VLAN ID in the "VLAN ID" input box.
Range of values: 1 ... 4094
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● VLAN ID
Shows the VLAN ID. The VLAN ID (a number between 1 and 4094) can only be assigned
once when creating a new data record and can then no longer be changed. To make a
change, the entire data record must be deleted and created again. Up to 24 VLANs can be
defined.
● Name
Enter a name for the VLAN. The name only provides information and has no effect on the
configuration. The length is a maximum of 32 characters.
262
Sets the mode "VLAN-aware" for the device. In this mode, VLAN information is taken into
account.
Sets the mode "VLAN-unaware" for the device. In this mode, VLAN tags are not changed
but are forwarded transparently. The VLAN priority is evaluated for CoS. In this mode,
you cannot create any VLANs. Only a management VLAN is available: VLAN 1.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w1740Scalance w1780 seriesScalance w1740 seriesScalance w1788-2 m12 eecScalance w1788-1 m12Scalance w1788-2 m12 ... Show all

Table of Contents