Configuring with Web Based Management
6.4 "Information" menu
Description
● Severity Filters
You can filter the entries in the table according to severity. To display all the entries, enable
or disable all parameters.
Note
A maximum of 2000 entries in the table are possible for each severity. If the maximum
number of entries is reached for a severity, the oldest entries of this severity are overwritten
in the table. The table remains permanently in the memory.
– Info
– Warning
– Critical
The table has the following columns:
● Restart
Counts the number of restarts since you last reset to factory settings and shows the device
restart after which the corresponding event occurred.
● System Up Time
Shows the time the device has been running since the last restart when the described event
occurred.
● System Time
Shows the date and time when the described event occurred.
● Severity
Shows the severity of the message.
● Log Message
Displays a brief description of the event that has occurred. You will find the list of possible
messages in Appendix D (Page 349) of the configuration manual.
If the system time is set, the time is also displayed at which the event occurred.
96
Information
When this parameter is enabled, all entries of the category "Info" are displayed.
Warnings
When this parameter is enabled, all entries of the category "Warning" are displayed.
Critical
When this parameter is enabled, all entries of the category "Critical" are displayed.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03