Configuring with Web Based Management
6.5 "System" menu
● Subnet Mask
If necessary, adapt the subnet mask of the device.
● Gateway Address
If necessary, specify the IPv4 address of the gateway.
● Status Device Name
– Discovered: The set device name is used.
– Configured: The device was assigned a new device name.
● Status IP Address
– Discovered/IP: The device uses a static IPv4 address.
– Discovered/DHCP: The device has obtained the IPv4 address from a DHCP server.
– Configured: The device was assigned a new IPv4 address.
● Timeout
Specify the time for flashing. When the time elapses, flashing stops.
● Flash
Makes the port LEDs of the selected device flash.
Procedure
1. Select the TIA interface.
2. To show all devices that can be reached via the TIA interface, click the "Browse" button.
3. Adapt the desired properties.
4. Click the "Set Values" button.
The status of the modified properties changes to "Configured".
5. To ensure that the properties were applied correctly, click the "Browse" button again.
The status of the modified properties changes to "Discovered".
218
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03