Siemens SCALANCE W1780 Configuration Manual page 282

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.7 "Layer 2" menu
Applications
PROFINET uses LLDP for topology diagnostics. In the default setting, LLDP is enabled for all
ports; in other words, LLDP frames are sent and received on all ports. With this function, you
have the option of enabling or disabling sending and/or receiving per port.
Description
Table 1 has the following columns:
● All Ports
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2
remains unchanged.
● Copy to Table
When you click this button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the port.
● Setting
Specify the LLDP functionality. The following options are available:
– Tx
– Rx
– Rx & Tx
– "-" (Disabled)
282
This port can only send LLDP frames.
This port can only receive LLDP frames.
This port can receive and send LLDP frames.
This port can neither receive nor send LLDP frames.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management