Chapter 4
Troubleshooting Procedures
Installing the Model 8000 Remote Access Concentrator
4-12
Table 4-6. Errors from Last ERPC Layer Invocation
Error
Description
H/W errors
The RAC sensed a hardware error during message
transmission or reception. This error indicates a fault with
the RAC LAN interface. Use the net command to isolate
the problem (see
Msgs from
The RAC received a message from an incorrect host. This
wrong host
indicates that the RAC received, and ignored, an unsolicited
packet.
Rsp T/O's
The RAC never received a correctly formatted response
from the correct host, or any response from any load server
host.
Msgs of
The correct host sent a message to the RAC, but the
wrong type
message was not a correctly formatted response to the
transmitted request.
Table 4-7. Errors from Last Read Request
Error
Msgs with wrong
size
ERPC layer errors
Aborts rx'd
net
on page 3-19).
Description
The correct host responded to the read request, but
the data size is incorrect.
See
Table
4-6.
The host's BFS transmitted an abort in response to
the RAC's read request. Run erpcd –D on the host to
obtain more information.