1. Installation
Earth/ground
1-16
The CPV valve terminal has an earth/ground connec-
tion on the left-hand end plate.
PLEASE NOTE
• Connect the earth cable of the left-hand end plate
to the earth potential with low impedance (short
cable with large diameter).
You will thereby avoid interference as a result of elec-
tromagnetic influences.
Remark:
Protection against electric shock (protection against di-
rect and indirect contact) is guaranteed on Festo valve
terminals by the use of PELV power units in accord-
ance with EN 60204-1 / IEC 204. The valve terminals
must be earthed in order to ensure their function (e.g.
EMC).