Cpv Valve Terminal With Individual Tubing; Fitting Variants - Festo CPV -VI Series Manual

Cpv valve terminal
Hide thumbs Also See for CPV -VI Series:
Table of Contents

Advertisement

2. Fitting
2.1

CPV valve terminal with individual tubing

Festo P.BE−CPV−EN en 0503g
Warning
Switch off the following power supplies before undertaking
installation and/or maintenance work:
the compressed air supply
·
the power supply for the valve solenoid coils
·
You can thereby avoid:
uncontrolled movements of loose tubing,
unexpected movements of the connected actuators,
non−defined switching states of the electronic compo
nents.

Fitting variants

The CPV valve terminal with individual tubing has already
been prepared for integration in a system or machine for the
following fitting variants:
Fitting onto a wall
Fitting onto a hat rail
Fitting onto a stand
Please note
If vibrations, which exceed the following values, occur on
your application:
0.15 mm path at 10...58 Hz
2 g acceleration at 58...150 Hz
You should mount the CPV14 or CPV18 valve terminal on a
wall or on a stand.
2−3