Preparing To Replace A Disk Drive Or Solid-State Drive By Using The Iprconfig Command; Replacing A Disk Drive Or Solid-State Drive In The 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, Or 8205-E6D System Or Expansion Unit - IBM 8202-E4B Manual

Disk drives or solid-state drives
Hide thumbs Also See for 8202-E4B:
Table of Contents

Advertisement

1. Complete the prerequisite tasks. For instructions, see "Before you begin" on page 137.
2. Find the package that contains the new drive.
Attention: Drives are fragile. Handle with care.
3. Remove the drive from the static-protective package.
4. Proceed to preparing to replace a drive by using the iprconfig command.
Preparing to replace a disk drive or solid-state drive by using the iprconfig
command
Complete the following steps before you replace a disk drive or solid-state drive by using the iprconfig
command:
1. From the IBM Power RAID Configuration Utility display, select Work with disk unit recovery. Press
Enter.
2. From the Work with Disk Unit Recovery display, select Concurrent add device. Press Enter.
A Concurrent Device Add display similar to the following example is shown.
Choose a single location for add operations
1=Select
OPT Name
Platform Location
--- ------ -------------------------- ------------------------- ----------------
U5887.001.Z065075-P1-D1
U5887.001.Z065075-P1-D6
U5887.001.Z065075-P1-D7
U5887.001.Z065075-P1-D8
U5887.001.Z065075-P1-D9
e=Exit
q=Cancel
t=Toggle
Figure 45. Example Concurrent Device Add display
3. Type 1 (Select) next to the location from which you removed the disk drive or solid-state drive.
The Verify Device Concurrent Add display is shown. The service indicator flashes for that drive slot.
Choose from the following options:
v If you are replacing a drive in a system or expansion unit, proceed to "Replacing a disk drive or
solid-state drive in the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D system or
expansion unit."
v If you are replacing a drive in the 5888 PCIe storage enclosure, proceed to "Replacing a solid-state
drive in the 5888 PCIe storage enclosure" on page 70.
v If you are replacing a drive in the EDR1 PCIe storage enclosure, proceed to "Replacing a solid-state
drive in the EDR1 PCIe storage enclosure" on page 71.
Replacing a disk drive or solid-state drive in the 8202-E4B, 8202-E4C, 8202-E4D,
8205-E6B, 8205-E6C, or 8205-E6D system or expansion unit
Complete the following steps to replace a disk drive or solid-state drive in a system or in an expansion
unit:
Concurrent Device Add
Description
Status
Empty
Empty
Empty
Empty
Empty
Disk drives or solid-state drives
69

Hide quick links: