NetApp StorageGRID SG5700 Series Hardware Installation And Maintenance Manual page 39

Integrated storage and computing platform
Hide thumbs Also See for StorageGRID SG5700 Series:
Table of Contents

Advertisement

Port bond mode is set to Fixed.
Network bond mode for the Grid Network is set to Active-Backup.
The Admin Network is enabled, and the network bond mode is set to Independent.
The Client Network is disabled.
2. If you plan to use the 25-GbE link speed for the 10/25 GbE ports, select 25GbE from the Link
speed drop-down list.
The network switches you are using for the Grid Network and the Client Network must also
support and be configured for this speed. SFP28 transceivers must be installed in the ports.
3. Enable or disable the StorageGRID networks you plan to use.
The Grid Network is required. You cannot disable this network.
Configuring the hardware | 39