VLT
AutomationDrive FC 300 Operating
Instructions
4.4.16 16-** Data Readouts
Par.
Parameter description
No. #
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-15 Frequency [%]
16-16 Torque [Nm]
16-17 Speed [RPM]
16-18 Motor Thermal
16-19 KTY sensor temperature
16-20 Motor Angle
16-21 Torque [%] High Res.
16-22 Torque [%]
16-25 Torque [Nm] High
16-3* Drive Status
16-30 DC Link Voltage
16-32 Brake Energy /s
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-41 LCP Bottom Statusline
16-49 Current Fault Source
16-5* Ref. & Feedb.
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Reference
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 54 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Freq. Input #29 [Hz]
16-68 Freq. Input #33 [Hz]
16-69 Pulse Output #27 [Hz]
16-70 Pulse Output #29 [Hz]
16-71 Relay Output [bin]
16-72 Counter A
16-73 Counter B
16-74 Prec. Stop Counter
16-75 Analog In X30/11
16-76 Analog In X30/12
16-77 Analog Out X30/8 [mA]
16-78 Analog Out X45/1 [mA]
16-79 Analog Out X45/3 [mA]
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm. Option STW
16-85 FC Port CTW 1
16-86 FC Port REF 1
16-9* Diagnosis Readouts
16-90 Alarm Word
16-91 Alarm Word 2
16-92 Warning Word
16-93 Warning Word 2
16-94 Ext. Status Word
Default value
0 N/A
All set-ups
0.000 ReferenceFeedbackU-
nit
All set-ups
0.0 %
All set-ups
0 N/A
All set-ups
0.00 %
All set-ups
0.00 CustomReadoutUnit
All set-ups
0.00 kW
All set-ups
0.00 hp
All set-ups
0.0 V
All set-ups
0.0 Hz
All set-ups
0.00 A
All set-ups
0.00 %
All set-ups
0.0 Nm
All set-ups
0 RPM
All set-ups
0 %
All set-ups
0 °C
All set-ups
0 N/A
All set-ups
0.0 %
All set-ups
0 %
All set-ups
0.0 Nm
All set-ups
0 V
All set-ups
0.000 kW
All set-ups
0.000 kW
All set-ups
0 °C
All set-ups
0 %
All set-ups
SR
All set-ups
SR
All set-ups
0 N/A
All set-ups
0 °C
All set-ups
[0] No
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0.0 N/A
All set-ups
0.0 N/A
All set-ups
0.000 ReferenceFeedbackU-
nit
All set-ups
0.00 N/A
All set-ups
0 N/A
All set-ups
[0] Current
All set-ups
0.000 N/A
All set-ups
[0] Current
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
®
MG.33.AG.02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change dur-
only
ing opera-
tion
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
x
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
x
FALSE
FALSE
FALSE
x
FALSE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
4 How to Programme
Conver-
Type
sion index
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
4
-2
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int16
67
Int32
0
Uint8
100
Int16
0
Uint16
-1
Int16
0
Int16
-1
Int32
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
-
Uint8
VisStr[
0
50]
0
Uint8
-1
Int16
-1
Int16
-3
Int32
-2
Int16
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
0
Int32
0
Int32
0
Int32
0
Int16
0
Int32
0
Int32
0
Uint32
-3
Int32
-3
Int32
-3
Int16
-3
Int16
-3
Int16
0
V2
0
N2
0
V2
0
V2
0
N2
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
87