Danfoss VLT AutomationDrive FC 301 Operating Instructions Manual page 80

Frequency converter
Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

4 How to Programme
4.4.9 8-** Comm. and Options
Par.
Parameter description
No. #
8-0* General Settings
8-01
Control Site
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-07
Diagnosis Trigger
8-08
Readout Filtering
4
8-1* Ctrl. Word Settings
8-10
Control Word Profile
8-13
Configurable Status Word STW
8-14
Configurable Control Word CTW
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram selection
8-41
Parameters for signals
8-42
PCD write configuration
8-43
PCD read configuration
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-9* Bus Jog
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
80
Default value
4-set-up
[0] Digital and ctrl.word
All set-ups
null
All set-ups
1.0 s
1 set-up
null
1 set-up
[1] Resume set-up
1 set-up
[0] Do not reset
All set-ups
[0] Disable
2 set-ups
null
All set-ups
[0] FC profile
All set-ups
null
All set-ups
[1] Profile default
All set-ups
[0] FC
1 set-up
1 N/A
1 set-up
null
1 set-up
[0] Even Parity, 1 Stop Bit
1 set-up
0 ms
2 set-ups
10 ms
All set-ups
SR
1 set-up
SR
1 set-up
[1] Standard telegram 1
2 set-ups
0
All set-ups
SR
All set-ups
SR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
100 RPM
All set-ups
200 RPM
All set-ups
®
MG.33.AG.02 - VLT
is a registered Danfoss trademark
®
VLT
AutomationDrive FC 300 Operating
FC 302
Change dur-
Conver-
only
ing opera-
sion index
tion
TRUE
-
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-5
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
67
TRUE
67
Instructions
Type
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents