VLT
AutomationDrive FC 300 Operating
Instructions
4.4.2 1-** Load/Motor
Par.
Parameter description
No. #
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-02
Flux Motor Feedback Source
1-03
Torque Characteristics
1-04
Overload Mode
1-05
Local Mode Configuration
1-06
Clockwise Direction
1-1* Motor Selection
1-10
Motor Construction
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-33
Stator Leakage Reactance (X1)
1-34
Rotor Leakage Reactance (X2)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-37
d-axis Inductance (Ld)
1-39
Motor Poles
1-40
Back EMF at 1000 RPM
1-41
Motor Angle Offset
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-51
Min Speed Normal Magnetising [RPM]
1-52
Min Speed Normal Magnetising [Hz]
1-53
Model Shift Frequency
1-54
Voltage reduction in fieldweakening
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-67
Load Type
1-68
Minimum Inertia
1-69
Maximum Inertia
1-7* Start Adjustments
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-74
Start Speed [RPM]
1-75
Start Speed [Hz]
1-76
Start Current
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-83
Precise Stop Function
1-84
Precise Stop Counter Value
1-85
Precise Stop Speed Compensation Delay
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Resource
1-95
KTY Sensor Type
1-96
KTY Thermistor Resource
1-97
KTY Threshold level
Default value
null
All set-ups
null
All set-ups
[1] 24V encoder
All set-ups
[0] Constant torque
All set-ups
[0] High torque
All set-ups
[2] As mode par 1-00
All set-ups
[0] Normal
All set-ups
[0] Asynchron
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
[0] Off
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
0 N/A
All set-ups
100 %
All set-ups
SR
All set-ups
SR
All set-ups
SR
All set-ups
0 V
All set-ups
SR
All set-ups
SR
All set-ups
30 %
All set-ups
200 %
All set-ups
100 %
All set-ups
100 %
All set-ups
SR
All set-ups
SR
All set-ups
100 %
All set-ups
5 ms
All set-ups
100 %
All set-ups
[0] Passive load
All set-ups
SR
All set-ups
SR
All set-ups
0.0 s
All set-ups
[2] Coast/delay time
All set-ups
[0] Disabled
All set-ups
SR
All set-ups
SR
All set-ups
0.00 A
All set-ups
[0] Coast
All set-ups
SR
All set-ups
SR
All set-ups
[0] Precise ramp stop
All set-ups
100000 N/A
All set-ups
10 ms
All set-ups
[0] No protection
All set-ups
[0] No
All set-ups
[0] None
All set-ups
[0] KTY Sensor 1
All set-ups
[0] None
All set-ups
80 °C
®
MG.33.AG.02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change dur-
only
ing opera-
tion
TRUE
FALSE
x
FALSE
TRUE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
x
FALSE
FALSE
x
FALSE
FALSE
TRUE
TRUE
TRUE
x
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
x
TRUE
x
TRUE
x
FALSE
x
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
x
TRUE
x
TRUE
1 set-up
x
TRUE
4 How to Programme
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
4
-
Uint8
-2
Uint32
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
67
Uint16
-1
Uint32
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-4
Int32
0
Uint8
0
Uint16
0
Int16
0
Uint16
67
Uint16
-1
Uint16
-1
Uint16
0
Uint8
-1
Uint16
-1
Uint16
0
Uint16
0
Uint16
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
0
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-1
Uint8
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
-2
Uint32
-
Uint8
67
Uint16
-1
Uint16
-
Uint8
0
Uint32
-3
Uint8
-
Uint8
-
Uint16
-
Uint8
-
Uint8
-
Uint8
100
Int16
73