Parameter Descriptions
13-15 RS-FF Operand S
Option:
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100]
RS Flipflop 6
[101]
RS Flipflop 7
13-16 RS-FF Operand R
Option:
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
MG34M302 - VLT
®
Operating Instructions VLT
CDS302 and CDS303
13-16 RS-FF Operand R
Function:
Option:
[45]
[46]
[47]
[48]
[50]
[51]
[60]
Function:
[61]
[70]
[71]
[72]
[73]
[74]
[75]
[76]
[77]
[78]
[79]
[80]
[81]
[82]
[83]
[84]
[85]
[90]
[91]
[92]
[93]
[94]
[95]
[96]
[97]
[98]
[99]
[100]
[101]
6.10.5 13-2* Timers
Use the result (TRUE or FALSE) from timers directly to
define an event (see 13-51 SL Controller Event), or as
boolean input in a logic rule (see 13-40 Logic Rule Boolean
1, 13-42 Logic Rule Boolean 2 or 13-44 Logic Rule Boolean 3).
A timer is only FALSE when started by an action (i.e. [29]
Start timer 1) until the timer value entered in this
parameter is elapsed. Then it becomes TRUE again.
All parameters in this parameter group are array
parameters with index 0 to 2. Select index 0 to program
Timer 0, select index 1 to program Timer 1, and so on.
®
is a registered Danfoss trademark/Commercial Compressor
Left key
Right key
Up key
Down key
Comparator 4
Comparator 5
Logic rule 4
Logic rule 5
SL Time-out 3
SL Time-out 4
SL Time-out 5
SL Time-out 6
SL Time-out 7
Start command given
Digital input x30/2
Digital input x30/3
Digital input x30/4
Digital input x46/1
Digital input x46/3
Digital input x46/5
Digital input x46/7
Digital input x46/9
Digital input x46/11
Digital input x46/13
ATEX ETR cur. warning
ATEX ETR cur. alarm
ATEX ETR freq. warning
ATEX ETR freq. alarm
RS Flipflop 0
RS Flipflop 1
RS Flipflop 2
RS Flipflop 3
RS Flipflop 4
RS Flipflop 5
RS Flipflop 6
RS Flipflop 7