Danfoss VLT CDS302 Operating Instructions Manual page 68

Table of Contents

Advertisement

Parameter Descriptions
Bit 0
Digital Output Terminal 27
Bit 1
Digital Output Terminal 29
Bit 2
Digital Output Terminal X 30/6
Bit 3
Digital Output Terminal X 30/7
Bit 4
Relay 1 output terminal
Bit 5
Relay 2 output terminal
Bit 6
Option B Relay 1 output terminal
Bit 7
Option B Relay 2 output terminal
Bit 8
Option B Relay 3 output terminal
Bit 9-15
Reserved for future terminals
Bit 16
Option C Relay 1 output terminal
Bit 17
Option C Relay 2 output terminal
Bit 18
Option C Relay 3 output terminal
Bit 19
Option C Relay 4 output terminal
6
6
Bit 20
Option C Relay 5 output terminal
Bit 21
Option C Relay 6 output terminal
Bit 22
Option C Relay 7 output terminal
Bit 23
Option C Relay 8 output terminal
Bit 24-31
Reserved for future terminals
Table 6.8
5-93 Pulse Out #27 Bus Control
Range:
0.00 %
[0.00 - 100.00
*
%]
5-95 Pulse Out #29 Bus Control
Range:
0.00 %
[0.00 - 100.00
*
%]
68
Operating Instructions VLT
Function:
Set the output frequency transferred to
the output terminal 27 when the
terminal is configured as [45] Bus
Controlled in 5-60 Terminal 27 Pulse
Output Variable.
Function:
Set the output frequency transferred to
the output terminal 29 when the
terminal is configured as [45] Bus
Controlled in 5-63 Terminal 29 Pulse
Output Variable.
®