Programming Commander DELTA
Icon
Parameter
Seam begin bartack parameters
Bartack at seam begin
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections.
If the sewing direction is changed, a new
section is started. The number of sections
in a bartack can be set here.
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Setting options Max. sewing speed
Menu item Setting 1
linear
Max.
sewing speed
Value range 0000 – 4000
Min. Material thickness
Value range 00.0 – 10.0 [mm]
Max. Material thickness
Value range 00.0 – 10.0 [mm]
5.8.6
Setting the Seam Begin/Segment Begin
parameters
There are various options for setting the Seam Begin/Segment
Begin parameters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Setting 2
Maximum speed reached
at the upper material
thickness limit.
Material thickness at
which the increase in
sewing speed should
start.
Material thickness up to
which the increase in
sewing speed should
occur.
Setting
Value range
On/Off
Value range
01 - 50
Value range
01 - 50
Value range
01 - 99