Code Type
2479 Error
2480 Error
2481 Error
2483 Error
2484 Error
2485 Error
2487 Error
2488 Error
2501 Error
2505 Error
182
Possible cause
Stepper motor card X60
Current sensor failure
(Edge guide)
Stepper motor card X60
Incorrect stepper motor
direction of rotation
(Edge guide)
Stepper motor card X60
Reference drive failure
(Edge guide)
Stepper motor card X60
overcurrent (Edge guide)
Stepper motor card X60
parameter init (Edge guide)
Stepper motor card X60
insulation error (Edge guide)
Stepper motor card X60
transport interval failure
(Edge guide)
Stepper motor card X60
Reference drive failure
(Edge guide)
Stepper motor card X70
reference run timeout
(upper Puller)
Stepper motor card X70
stepper motor blockage
(upper Puller)
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Remedial action
• Replace control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine
distributor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Perform a software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
Troubleshooting