Code Type
9922 Warning
9923 Warning
9924 Warning
9925 Warning
9926 Warning
9927 Warning
9928 Warning
9929 Warning
9930 Warning
9931 Information Bobbin Wind mode
9932 Information No program available
192
Possible cause
Service Stop
Update required
Security key generated
Security Key changed!
Please Confirm Reset
Reset
Referencing?
Not enough thread available
Empty bobbin
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Remedial action
• Check the Service Stop button
• Check 24V
• Replace control
• Press OK for Restart or ESC for cancel
• Creation of a security key on a USB key
• Overwrite Security Key?
• Really reset?
• Reset successfully
• Press pedal backwards
(pedal position-2)
• Please insert a full bobbin
• Please insert a full bobbin
• Press pedal backwards exit bobbin wind
mode
• Automatic mode is not available
without a seam program. Please use
programming mode to create a new
seam program.