DURKOPP ADLER M-Type Delta D867 Operating Instructions Manual page 88

Hide thumbs Also See for M-Type Delta D867:
Table of Contents

Advertisement

Menu item
Off
Monitor
Monitor mode can only be used if
the additional equipment of the
remaining thread monitor is present
on the machine.
Monitor mode allows for optical
monitoring of the bobbin.
86
5.6.3.1 Setting the Bobbin monitor mode parameters
The amount of remaining thread on the bobbin can be monitored
optically or by software using this setting.
Setting option 1
Sewing stop
Sewing stops and a notice is shown
on the display when the bobbin is
detected to be nearly empty. If the
parameter is not activated, only the
LEDs on the machine arm give a
warning if the bobbin is empty.
Sewing foot lower position Value range
t Clean
Duration for which the lens is blown
clear with compressed air.
The process takes place as the
thread is cut.
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Programming Commander DELTA
Setting option 2
Value range
On/Off
On/Off
Value range
0000 – 5000 [ms]

Advertisement

Table of Contents
loading

Table of Contents