DURKOPP ADLER M-Type Delta D867 Operating Instructions Manual page 181

Hide thumbs Also See for M-Type Delta D867:
Table of Contents

Advertisement

Troubleshooting
Code Type
2288 Error
2301 Error
2305 Error
2321 Error
2322 Error
2330 Error
2331 Error
2352 Error
2371 Error
2372 Error
2373 Error
2374 Error
2375 Error
2376 Error
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Possible cause
Stepper motor card X40
Reference drive failure
(Foot lifting)
Stepper motor card X50
Reference drive failure
(Stitch length)
Stepper motor card X50
stepper motor blockage
Stepper motor card X50
encoder plug (Sub-D, 9-pin)
not connected
Stepper motor card X50
flywheel position not found
Stepper motor card X50 not
responding
Stepper motor card X50
parameter init error
Stepper motor card X50
overcurrent
Stepper motor card X50
Watchdog (sewing foot lift)
Stepper motor card X50 motor
overload / overvoltage /
overcurrent (Foot stroke)
Stepper motor card X50
Sewing motor encoder not
connected(Foot stroke)
Stepper motor card X50
Sewing motor encoder not init
(Foot stroke)
Stepper motor card X50 Init
Position not found
(Foot stroke)
Stepper motor card X50 not
Enabled (Foot stroke)
Remedial action
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control,
use the correct interface
• Check stepper motor 1 for stiff
movement
• Perform a software update
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Perform a software update
• Check selection of class
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
179