Code Type
2405 Error
2421 Error
2422 Error
2430 Error
2431 Error
2471 Error
2472 Error
2473 Error
2474 Error
2475 Error
2476 Error
2477 Error
2478 Error
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Possible cause
Stepper motor card X60
stepper motor blockage
(Edge guide)
Stepper motor card X60
encoder plug (Sub-D, 9-pin)
not connected
Stepper motor card X60
flywheel position not found
Stepper motor card X60 not
responding
Stepper motor card X60
parameter init error
Stepper motor card X60
Watchdog (Edge guide)
Stepper motor card X60 motor
overload / overvoltage /
overcurrent (Edge guide)
Stepper motor card X60
Sewing motor encoder not
connected(Edge guide)
Stepper motor card X60
Sewing motor encoder not init
(Edge guide)
Stepper motor card X60 Init
Position not found
(Edge guide)
Stepper motor card X60 not
Enabled (Edge guide)
Stepper motor card X60
Overload (Edge guide)
Stepper motor card X60
Encoder failure (Edge guide)
Remedial action
• Check for stiff movement
• Connect encoder cable to the control,
use the correct interface
• Check stepper motor 1 for stiff
movement
• Perform a software update
• Replace control
• Perform a software update
• Check selection of class
• Perform a software update
• Check selection of class
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
181