Code Type
1004 Error
1005 Error
1006 Error
1007 Error
1008 Error
1010 Error
1011 Error
1012 Error
1054 Error
1055 Error
1060 Error
1061 Error
174
Possible cause
Incorrect sewing motor
direction of rotation
Motor blocked
Maximum speed exceeded
Error in the reference run
Sewing motor encoder error
External synchronizer plug
(Sub-D, 9-pin) not connected
Encoder Z pulse missing
Synchronizer fault
Internal short circuit
Sewing motor overload
Sewing motor overload /
overvoltage /overcurrent
Sewing motor overload /
overvoltage /overcurrent
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Remedial action
• Replace encoder
• Check motor plug assignment and
change it if necessary
• Check wiring in machine distributor and
change it, if necessary
• Test motor phases and check for correct
value
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Replace encoder
• Perform reset
• Check class (t 51 04)
• Replace encoder
• Check for stiff movement
• Replace encoder
• Connect cable of external synchronizer
to control, make sure that interface
(Sync) is correct
• Only recommended for machines with
transmission!
• Switch off the control, use handwheel
to turn, and switch on the control again
• If error is not corrected, check encoder
• Replace synchronizer
• Replace control
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
Troubleshooting