E883 Engine Failed To Stop When Fuel Solenoid Disengaged - Perkins 1104E Series Troubleshooting Manual

Table of Contents

Advertisement

RENR2696-01
Test Step 2.
Perform the following diagnostic procedure: "CAN
Data Link Circuit - Test"
Results:
OK – STOP.
E883 Engine Failed To
Stop When Fuel Solenoid
Disengaged
Conditions Which Generate This Code:
The engine shutdown was slow when the keyswitch
was turned to the OFF position.
The engine failed to stop when the ECM disabled
the fuel injection pump.
The engine failed to shutdown when the keyswitch
was turned to the OFF position.
System Response:
The ECM attempts to shut down the engine by
instructing the fuel injection pump to stop fuel
injection.
The event code is logged in the ECM memory.
Possible Performance Effect:
Slow engine shutdown
Troubleshooting:
No troubleshooting will be required unless the
diagnostic code 1684-10 is active.
Test Step 1.
Use a multimeter to check the following connections:
J1:1
P40:5
Ensure that the problem has been eliminated.
Results:
Check for active diagnostic codes – STOP.
Test Step 2.
Connect a test ECM to the engine in order to
determine if the original ECM is causing the problem.
Note: The parameters of the test ECM must match
the parameters in the suspect ECM.
If the test ECM resolves the problem, reconnect the
suspect ECM.
Verify that the problem returns with the suspect ECM.
i01798193
If the problem returns, replace the suspect ECM.
Results:
OK – STOP.
Not OK – Proceed to Test Step 3.
Test Step 3.
Replace the fuel injection pump. Refer to Disassembly
and Assembly, "Fuel Injection Pump Remove and
Install".
Results:
OK – STOP.
91
Troubleshooting Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rh11-upRf11-up1106e seriesVk11-upRk11-up

Table of Contents