RENR2696-01
Result 3 The engine cranks but the engine will not
start regardless of the condition of the electronic
service tool.
Result 4 The engine will not crank regardless of the
condition of the electronic service tool.
Result 5 The engine starts but the electronic service
tool does not power up.
Results:
Result 1 – There is not a problem with the Data
Link at this time. If an intermittent condition exists,
thoroughly inspect all wiring and connectors.
Repair: Perform the following diagnostic
procedure:
Troubleshooting, "Electrical Connectors - Inspect"
STOP.
Result 2 – The electronic service tool displays
an error message. The ECM is receiving battery
power. Proceed to Test Step 3.
Result 3 –
Repair: Perform the following diagnostic
procedure:
Troubleshooting, "Engine Will Not Crank"
STOP.
Result 4 –
Repair: Perform the following diagnostic
procedure:
Troubleshooting, "Engine Cranks But Will Not
Start"
STOP.
Result 5 – The electronic service tool does not
power up or the communications adapter does not
power up. Ensure that the ECM is receiving the
correct battery power. Proceed to Test Step 4.
Test Step 3. Check the Battery Voltage at
the ECM.
A. Ensure that the electronic service tool is connected
to the J60 service tool connector.
B. Disconnect ECM connector P1 from ECM
connector J1.
C. Turn the keyswitch to the ON position.