Test Step 1. Check the Batteries
A. Measure no-load battery voltage at the battery
terminals.
Expected Result:
The battery voltage should be no less than 11.0 volts
for a 12 volt system.
The battery voltage should be no less than 22.0 volts
for a 24 volt system.
Results:
OK – Proceed to Test Step 2.
Not OK
Repair: Recharge the batteries or replace the
batteries. Verify that the repairs have eliminated
the problem.
STOP.