A. Thoroughly inspect the following terminal
connections on the P40 Fuel Injection Pump
Connector:
P40:6 - Pump Supply
P40:7 + Pump Supply
Refer to Troubleshooting, "Electrical Connectors
- Inspect".
B. Thoroughly inspect the following terminal
connections on the P20/J20 Machine Interface
Connector.
P20: 58 - Pump Supply
P20: 48 + Pump Supply
P20: 42 Pump Power Control
C. Perform a 45 N (10 lb) pull test on each of the
wires in the Machine Interface Connector that are
associated with the following connections:
P20:58 - Pump Supply
P20:48 + Pump Supply
P20:42 Pump Power Control
D. Check the ECM connector (Allen head screw) for
the proper torque of 6.0 N·m (55 lb in).
E. Check the harness and wiring for abrasions and
for pinch points from the battery to the ECM. Also,
check the harness and wiring for abrasions and
for pinch points from the keyswitch to the ECM.
Expected Result:
All connectors, pins, and sockets should be
completely coupled and/or inserted. The harness and
wiring should be free of corrosion, abrasion, and/or
pinch points.
Results:
OK – Proceed to Test Step 3.
Not OK – There is a problem with the wiring or
connectors. Repair the wiring and/or connectors or
replace the wiring and/or connectors. Verify that
the repair has eliminated the problem. STOP.