Perkins 1104E Series Troubleshooting Manual page 14

Table of Contents

Advertisement

14
Troubleshooting Section
Table 3
CID FMI Code
J Code FMI Code
0041 03
0041 04
0091 02
0091 03
0091 04
0091 08
0091 12
0100 03
0100 04
0100 10
0102 03
0102 04
0102 10
0105 03
0105 04
0110 03
0110 04
0168 02
0174 02
0247 09
0253 02
0262 03
0262 04
0266 02
0267 02
0320 02
0320 11
0321 02
0342 02
0590 02
0774 02
0774 03
0774 04
0774 08
0774 12
1627 03
1639 09
1684 00
J0678 03
8V Sensor Power Supply, voltage more than normal
J0678 04
8V Sensor Power Supply, voltage less than normal
J0091 02
Throttle Demand Sensor, erratic or intermittent
J0091 03
Throttle Demand Sensor, open circuit or shorted high
J0091 04
Throttle Demand Sensor, shorted low
J0091 08
Throttle Demand Sensor, abnormal signal
J0091-12
Throttle Demand Sensor, power supply failure
J0100 03
Engine Oil Pressure Sensor, open circuit or shorted high
J0100 04
Engine Oil Pressue Sensor, shorted low
Engine Oil Pressure Sensor, power supply open circuit
J0102 03
Intake Manifold Pressure Sensor, open circuit or shorted high
J0102 04
Intake Manifold Pressure Sensor, shorted low
Intake Manifold Pressure Sensor, power supply open circuit
J0105 03
Intake Manifold Temperature Sensor, open circuit or shorted high
J0105 04
Intake Manifold Temperature Sensor, shorted low
J0110 03
Engine Coolant Temperature Sensor, open circuit or shorted high
J0110 04
Engine Coolant Temperature Sensor, shorted low
J0168 02
Battery Voltage, intermittent or incorrect
J0174 02
Fuel Temperature Sensor, erratic or intermittent
J0639 09
J1939 Datalink, abnormal update
J0234 02
Incorrect ECM Software
J0620 03
5V Sensor Power Supply, voltage more than normal
J0620 04
5V Sensor Power Supply, voltage less than normal
Crank without injection, switch state incorrect
External Stop Switch, data erratic or incorrect
J0637 02
Speed and Timing Sensor, intermittent loss of signal
J0637 11
Speed and Timing Sensor, loss of signal
Diagnostic Reset Switch, intermittent or incorrect
J0723 02
Speed and Timing Sensor No.2, intermittent signal
ECM identified missing timing pulse
Throttle Demand Sensor No.2, erratic or intermittent
Throttle Demand Sensor No.2, open circuit or shorted high
Throttle Demand Sensor No.2, shorted low
Throttle Demand Sensor No.2, abnormal signal
Throttle Demand Sensor No.2, power supply failure
Fuel Pump Relay, did not turn off
Machine Security System Module, abnormal update
J1077 00
Fuel Injection Pump, fuel temperature more than normal
Fault Description
RENR2696-01
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rh11-upRf11-up1106e seriesVk11-upRk11-up

Table of Contents