Setting Up Read Points - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

RF600 system planning
4.7 Planning and installation of UHF read points
4.7.2.3

Setting up read points

The read point setup described in this section is performed using the Web Based
Management (WBM) and applies to the RF600 readers. You can find a detailed description
of the WBM in the configuration manual "SIMATIC RF600
(https://support.industry.siemens.com/cs/ww/en/ps/15081/man)".
Adjust antennas
Follow the steps below to optimize the antenna alignment:
1. Position the object fitted with a transponder and to be identified at the required read point.
2. Align the reader or the antenna so that its front points in the direction of the object
(transponder) to be identified.
Keep to the minimum distances between antennas and transponders to avoid antenna
errors.
When using linear antennas, make sure the polarization direction is correct.
3. In the "Settings - Adjust antenna" menu item, select the connected antenna and click the
"Start adjustment" button.
Figure 4-17
74
Optimizing the antenna alignment with the "Settings - Adjust antenna" menu item of the
WBM