Overview of the antenna parameters
Table 5- 7
Azimuth section
Elevation section
Typical antenna gain
in the frequency band 902 to 928 MHz
Antenna axis ratio
You will find more information on the antennas in the section "Guidelines for selecting RFID
UHF antennas (Page 51)".
5.2.2.2

Interpretation of radiation patterns

You can find detailed information on the interpretation in the section "Interpretation of
radiation patterns (Page 215)".
5.2.3

Installation / mounting

Requirement
NOTICE
Close unused connectors
Note that the readers only have the specified degree of protection when all connectors are
in use or when unused connectors are closed with the protective caps.
Emitted radiation
The transmitter complies with the requirements of Health Canada and the FCC limit values
for subjecting persons to HF radiation, provided that a minimum spacing of 26 cm exists
between antenna and person. When the antennas are installed, you must therefore ensure
that a minimum spacing of 26 cm is maintained between personnel and antennas.
Mounting/installing the device
You can mount the reader in the following ways:
● directly on a flat surface using the VESA 100 mounting system (torque ≃ 1.5 Nm).
The positions of the mounting holes for the device are shown in the section Dimension
drawing (Page 120).
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
Maximum linear electrical aperture angle at 915 MHz:
CAUTION
Readers
5.2 SIMATIC RF610R
Polarization (circular)
100°
100°
0 dBi
2 dB
115